Electrical Safety Certificate

Electrical Installation
Condition Report

NICEIC approved EICR inspections for landlords, homeowners, homebuyers and businesses. Fast turnaround, clear reports and full documentation — covering Staffordshire and the West Midlands.

EICR Key Facts
What you need to know
Landlord requirementEvery 5 years
Typical duration (house)3–4 hours
Certificate issuedSame day
Applies toAll property types
Carried out byNICEIC approved engineer
Report formatC1, C2, C3 coded
NICEIC✓ Approved inspector
5★ Google rated
What Is an EICR

Your Property's
Electrical Health Check

An Electrical Installation Condition Report (EICR) — also known as a periodic inspection or electrical safety certificate — is a formal assessment of the electrical installations within a property.

Carried out by a qualified, NICEIC approved electrician, it checks that your wiring, consumer unit, sockets, switches and earthing are all safe, in good working order and compliant with current UK electrical regulations (BS 7671).

The inspection doesn't just look at whether things are working — it identifies potential hazards, deterioration and any work that doesn't meet today's standards, even if it was acceptable when it was installed.

Checks all fixed electrical installations throughout the property
Identifies any damage, deterioration or dangerous wiring
Tests protective devices — RCDs, circuit breakers and fuses
Verifies earthing and bonding are adequate
Issues a formal certificate with coded observations
Book Your EICR
Electrician carrying out EICR inspection
£30,000 Maximum fine for landlords who fail to comply with EICR regulations
Who Needs an EICR

Required for Many.
Recommended for All.

An EICR isn't just a legal tick-box — it's genuine peace of mind that the electrics in your property are safe. Here's who needs one and how often.

Homeowners

Not a legal requirement for owner-occupiers, but strongly recommended — especially in older properties or if you've recently purchased a home and don't know the history of the electrics. An EICR identifies hidden risks before they become dangerous or costly to fix.

Every 10 yearsrecommended interval
Get peace of mind
Homebuyers

If you're buying a property, an EICR before exchange gives you a clear picture of the electrical condition. It can uncover costly remedial works that you can factor into negotiations — or walk away from altogether. Many mortgage lenders and insurers now request one.

Before purchasestrongly recommended
Book pre-purchase EICR
Businesses

Commercial premises have a duty of care to employees and visitors under the Electricity at Work Regulations 1989. A commercial EICR demonstrates compliance, protects against liability and is often required by insurers. We carry out EICRs for offices, retail units, warehouses and more.

Every 5 yearsrecommended for commercial
Commercial enquiry
The Inspection

What We
Check & Test

A thorough EICR covers every aspect of your fixed electrical installation. Here's what our inspectors examine:

Consumer Unit (Fuse Board)
Condition and type of unit
RCD and circuit breaker operation
Correct labelling of circuits
Overcurrent protection adequacy
Wiring & Circuits
Condition and age of wiring
Insulation resistance testing
Continuity of ring and radial circuits
Correct cable sizing for loads
Sockets, Switches & Light Fittings
Physical condition of accessories
Correct polarity at all outlets
Appropriate rating for location
Bathroom zone compliance
Earthing & Bonding
Main earthing conductor condition
Main and supplementary bonding
Earth fault loop impedance
Bonding to gas and water services
On The Day
Visual inspection

We walk through the property checking all visible electrical installations — consumer unit, sockets, switches, light fittings, wiring and accessories — for obvious damage or defects.

Dead testing

With circuits isolated, we perform continuity, insulation resistance and polarity tests. This requires brief interruptions to the power supply — we always warn you in advance.

Live testing

With circuits energised, we test earth fault loop impedance, RCD operation and prospective fault current. This verifies that protective devices will operate correctly in the event of a fault.

Report & certificate issued

We compile all findings into a formal EICR, issue your certificate and walk you through any observations. You'll have everything you need on the same day.

How Long Does It Take?

1-bed flat2–3 hours
2–3 bed house3–4 hours
4+ bed house4–6 hours
Commercial propertyQuoted individually
Certificate issuedSame day
Understanding Your Report

What Do the Codes Mean?

Every observation in your EICR is assigned a classification code. Here's what each one means and what action — if any — is required.

C1
Danger Present
Immediate Danger

A C1 means there is a risk of injury from electrical shock or burn right now. The hazard exists and requires immediate attention — the report will be marked Unsatisfactory.

Action required: Remedial work must be completed immediately before the property is used.
Live wires exposed and accessible
No RCD protection on bathroom circuits
Overloaded wiring showing burn marks
C2
Potentially Dangerous
Urgent Remedial Work

A C2 means the installation is not yet dangerous but could become so. It indicates a significant defect that requires urgent attention. The report will be marked Unsatisfactory.

Action required: Remedial work required as soon as possible. Must be rectified before the next inspection.
Old unprotected wiring in poor condition
Missing earth bonding connections
Inadequate overcurrent protection
C3
Improvement Recommended
Non-Urgent Improvement

A C3 means the installation is safe but doesn't meet current best practice. Improvement is recommended but not required for the EICR to be marked Satisfactory. A C3-only report is a pass.

No immediate action required — the property is safe. Improvements are recommended at your convenience.
Older wiring that meets old but not current standards
No RCD protection on sockets (older properties)
Single-pole switching in bathrooms
Satisfactory

The installation is safe for continued use. Only C3 observations (if any) are present. No remedial work is legally required, though improvements may be recommended. Landlords can legally continue to let the property.

Unsatisfactory

One or more C1 or C2 observations are present. The installation has defects that must be addressed. Landlords must carry out remedial works within 28 days (or sooner for C1s) and provide written confirmation of completion. We can carry out all remedial work.